We’re Rich!

Please remember, Our RV Adventures is an Amazon affiliate. When you do your shopping through any of the Amazon links here, including the Search Amazon box in the right sidebar, it won’t cost you any more, but we’ll get a small commission on everything you buy. Just click on the Amazon link, then shop as usual. Thanks.

Plus, many of you are sharing our blog with others using the “Share this:” buttons at the bottom of each blog. Again, Thanks.

Now we just have to figure out what to buy with it. A new rig, maybe?

Our son Chris brought our mail up to Brandi’s this past Sunday and last night I finally got a chance to go through it all. And here’s what I found.

A check as a settlement on a lawsuit. And a lawsuit that I didn’t know I was involved in. A check for a whole 16 cents!

16 cent ATTM Check

What’s even funnier about this is that it says it’s a sales tax settlement refund for overcharges on an AT&T Mobility Data Plan. But we’ve never had an AT&T Data Plan, or even an AT&T phone of any kind. We’ve always been with Verizon.

So I don’t know now. I guess we should split our largese with the kids. It’ll be their inheirance.

After monitoring my Progressive 50 amp EMS (Electrical Management System) a lot more closely the last two days, I’ve got a good idea what the problem is. At first I was thinking I maybe had a bad or floating ground, But watching the L-1 and L-2 voltages on the Progressive display told me different.

The two voltages go in opposite directions under load. When L-1 is showing 105 volts, L-2 might be showing 128 volts. Way too wide a spread. And just inside the Hi/Lo cutoffs of the Progressive EMS.

And even with both AC’s off, and nothing else on except the TV/Sat and the computer, we were only seeing about 111 – 113 volts, way too low. Last week at Lake Conroe we were seeing 120 to 122 volts at the same time of day.

To protect the rig, the Progressive will cut off power to the rig if the voltage goes over 130 volts or below 103 volts. And it doesn’t have to be on both L-1 and L-2, but either one of them. So when one voltage is at 104 and the other one is running at 128, a momentary change on either end can cause the EMS to drop out. So now I’ve got a good handle on what’s happening, but what’s actually causing the problem?

I said earlier that at first I thought it might be an floating ground. But seeing the opposite voltage swings says a open or high resistance neutral. And because it’s happened at two different sites in this ring, I suspect it might be located at the main panel or thereabouts.

So now it’s up to Jeff, the park electrical guy, to follow up on this. As far as us, Jan says we’re never parking in this area again. It’s too much drama.